SLAB THICKNESS 14 cm
DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 5100 kg
The Dynamic load for:
50 repetitions/day: 3200 kg
100 repetitions/day: 2950 kg
200 repetitions/day: 2640 kg
300 repetitions/day: 2410 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m4,5
Depth of cut joint: 4,5 cm
SLAB THICKNESS 14 cm
DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 5100 kg
The Dynamic load for:
50 repetitions/day: 3470 kg
100 repetitions/day: 3220 kg
200 repetitions/day: 2870 kg
300 repetitions/day: 2660 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m4,5
Depth of cut joint: 4,5 cm
SLAB THICKNESS 14 cm
DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 6000 kg
The Dynamic load for:
50 repetitions/day: 2530 kg
100 repetitions/day: 3270 kg
200 repetitions/day: 2950 kg
300 repetitions/day: 2735 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m4,5
Depth of cut joint: 4,5 cm
SLAB THICKNESS 14 cm
DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 6000 kg
The Dynamic load for:
50 repetitions/day: 3860 kg
100 repetitions/day: 3560 kg
200 repetitions/day: 3200 kg
300 repetitions/day: 2970 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m4,5
Depth of cut joint: 4,5 cm