CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 12 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 2280 kg
The Dynamic load for:
50 repetitions/day: 1630 kg
100 repetitions/day: 1506 kg
200 repetitions/day: 1348 kg
300 repetitions/day: 1250 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 12 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 2375 kg
The Dynamic load for:
50 repetitions/day: 1775 kg
100 repetitions/day: 1640 kg
200 repetitions/day: 1460 kg
300 repetitions/day: 1360 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 12 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 2400 kg
The Dynamic load for:
50 repetitions/day: 1700 kg
100 repetitions/day: 1585 kg
200 repetitions/day: 1420 kg
300 repetitions/day: 1310 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

 

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 12 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 2500 kg
The Dynamic load for:
50 repetitions/day: 1860 kg
100 repetitions/day: 1715 kg
200 repetitions/day: 1525 kg
300 repetitions/day: 1410 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

 

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 13 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 2518 kg
The Dynamic load for:
50 repetitions/day: 1877 kg
100 repetitions/day: 1735 kg
200 repetitions/day: 1554 kg
300 repetitions/day: 1442 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 13 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 2755 kg
The Dynamic load for:
50 repetitions/day: 2050 kg
100 repetitions/day: 1885 kg
200 repetitions/day: 1690 kg
300 repetitions/day: 1570 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 13 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 2650 kg
The Dynamic load for:
50 repetitions/day: 1973 kg
100 repetitions/day: 1802 kg
200 repetitions/day: 1635 kg
300 repetitions/day: 1520 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 13 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 2900 kg
The Dynamic load for:
50 repetitions/day: 2140 kg
100 repetitions/day: 1970 kg
200 repetitions/day: 1760 kg
300 repetitions/day: 1640 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3m - 3,5m
Outdoor slab: 2m - 3m
Depth of cut joint: 4 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 14 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 2850 kg
The Dynamic load for:
50 repetitions/day: 2150 kg
100 repetitions/day: 1978 kg
200 repetitions/day: 1775 kg
300 repetitions/day: 1650 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m
Depth of cut joint: 4,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 14 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 3040 kg
The Dynamic load for:
50 repetitions/day: 2330 kg
100 repetitions/day: 2150 kg
200 repetitions/day: 1930 kg
300 repetitions/day: 1785 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m
Depth of cut joint: 4,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 14 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 3000 kg
The Dynamic load for:
50 repetitions/day: 2250 kg
100 repetitions/day: 2070 kg
200 repetitions/day: 1865 kg
300 repetitions/day: 1740 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m
Depth of cut joint: 4,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 14 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 3200 kg
The Dynamic load for:
50 repetitions/day: 1640 kg
100 repetitions/day: 2250 kg
200 repetitions/day: 2020 kg
300 repetitions/day: 1860 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,5m - 4m
Outdoor slab: 2,5m - 3,5m
Depth of cut joint: 4,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 15 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 3230 kg
The Dynamic load for:
50 repetitions/day: 2425 kg
100 repetitions/day: 2240 kg
200 repetitions/day: 2005 kg
300 repetitions/day: 1858 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 15 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 3420 kg
The Dynamic load for:
50 repetitions/day: 2635 kg
100 repetitions/day: 2430 kg
200 repetitions/day: 2180 kg
300 repetitions/day: 2020 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 15 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 3400 kg
The Dynamic load for:
50 repetitions/day: 2540 kg
100 repetitions/day: 2365 kg
200 repetitions/day: 2100 kg
300 repetitions/day: 1950 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 15 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 3600 kg
The Dynamic load for:
50 repetitions/day: 2760 kg
100 repetitions/day: 2532 kg
200 repetitions/day: 2265 kg
300 repetitions/day: 2110 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 16 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 3515 kg
The Dynamic load for:
50 repetitions/day: 2720 kg
100 repetitions/day: 2510 kg
200 repetitions/day: 2250 kg
300 repetitions/day: 2085 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 16 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 3800 kg
The Dynamic load for:
50 repetitions/day: 2960 kg
100 repetitions/day: 2730 kg
200 repetitions/day: 2445 kg
300 repetitions/day: 2265 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 16 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
La carga puntual a flexotracción que la solera va a soportar por cada punto de apoyo es de 3700 kg
The Dynamic load for:
50 repetitions/day: 2850 kg
100 repetitions/day: 2640 kg
200 repetitions/day: 2350 kg
300 repetitions/day: 2180 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 16 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 4000 kg
The Dynamic load for:
50 repetitions/day: 3100 kg
100 repetitions/day: 2860 kg
200 repetitions/day: 2550 kg
300 repetitions/day: 2370 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 3,75m- 4,5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 17 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 3895 kg
The Dynamic load for:
50 repetitions/day: 3035 kg
100 repetitions/day: 2800 kg
200 repetitions/day: 2510 kg
300 repetitions/day: 2325 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 17 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 4180 kg
The Dynamic load for:
50 repetitions/day: 3300 kg
100 repetitions/day: 3040 kg
200 repetitions/day: 2725 kg
300 repetitions/day: 2525 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 17 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 4100 kg
The Dynamic load for:
50 repetitions/day: 3180 kg
100 repetitions/day: 2930 kg
200 repetitions/day: 2640 kg
300 repetitions/day: 24432 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 17 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 4400 kg
The Dynamic load for:
50 repetitions/day: 3450 kg
100 repetitions/day: 3180 kg
200 repetitions/day: 2850 kg
300 repetitions/day: 2635 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 5,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 18 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 4275 kg
The Dynamic load for:
50 repetitions/day: 3360 kg
100 repetitions/day: 3100 kg
200 repetitions/day: 2780 kg
300 repetitions/day: 2580 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 6 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 18 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 4560 kg
The Dynamic load for:
50 repetitions/day: 3650 kg
100 repetitions/day: 3375 kg
200 repetitions/day: 3020 kg
300 repetitions/day: 2800 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 6 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 18 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 4500 kg
The Dynamic load for:
50 repetitions/day: 3500 kg
100 repetitions/day: 3250 kg
200 repetitions/day: 2900 kg
300 repetitions/day: 2700 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 6 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 18 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 4800 kg
The Dynamic load for:
50 repetitions/day: 3820 kg
100 repetitions/day: 3530 kg
200 repetitions/day: 3155 kg
300 repetitions/day: 2945 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4m - 5m
Outdoor slab: 3,5m - 4m
Depth of cut joint: 6 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 19 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 4655 kg
The Dynamic load for:
50 repetitions/day: 3710 kg
100 repetitions/day: 3420 kg
200 repetitions/day: 3065 kg
300 repetitions/day: 2840 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 19 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 4940 kg
The Dynamic load for:
50 repetitions/day: 4025 kg
100 repetitions/day: 3725 kg
200 repetitions/day: 3330 kg
300 repetitions/day: 3090 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 19 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 4900 kg
The Dynamic load for:
50 repetitions/day: 3890 kg
100 repetitions/day: 3582 kg
200 repetitions/day: 3225 kg
300 repetitions/day: 2988 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 19 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 5200 kg
The Dynamic load for:
50 repetitions/day: 4200 kg
100 repetitions/day: 3900 kg
200 repetitions/day: 3490 kg
300 repetitions/day: 3240 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 20 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 5035 kg
The Dynamic load for:
50 repetitions/day: 4070 kg
100 repetitions/day: 3760 kg
200 repetitions/day: 3370 kg
300 repetitions/day: 3120 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 20 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 5415 kg
The Dynamic load for:
50 repetitions/day: 4420 kg
100 repetitions/day: 4085 kg
200 repetitions/day: 3660 kg
300 repetitions/day: 3390 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 20 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 5300 kg
The Dynamic load for:
50 repetitions/day: 4270 kg
100 repetitions/day: 3940 kg
200 repetitions/day: 3540 kg
300 repetitions/day: 3280 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 20 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 5700 kg
The Dynamic load for:
50 repetitions/day: 4637 kg
100 repetitions/day: 4270 kg
200 repetitions/day: 3824 kg
300 repetitions/day: 3550 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,25m - 5,5m
Outdoor slab: 4m - 5m
Depth of cut joint: 6,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 21 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 5510 kg
The Dynamic load for:
50 repetitions/day: 4450 kg
100 repetitions/day: 4100 kg
200 repetitions/day: 3680 kg
300 repetitions/day: 3410 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4m - 5m
Depth of cut joint: 7 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 21 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 5795 kg
The Dynamic load for:
50 repetitions/day: 4830 kg
100 repetitions/day: 4460 kg
200 repetitions/day: 3990 kg
300 repetitions/day: 3700 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4m - 5m
Depth of cut joint: 7 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 21 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 5800 kg
The Dynamic load for:
50 repetitions/day: 4680 kg
100 repetitions/day: 4300 kg
200 repetitions/day: 3855 kg
300 repetitions/day: 3570 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4m - 5m
Depth of cut joint: 7 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 21 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 6100 kg
The Dynamic load for:
50 repetitions/day: 5050 kg
100 repetitions/day: 4670 kg
200 repetitions/day: 4198 kg
300 repetitions/day: 3892 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4m - 5m
Depth of cut joint: 7 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 22 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 5890 kg
The Dynamic load for:
50 repetitions/day: 4840 kg
100 repetitions/day: 4460 kg
200 repetitions/day: 4000 kg
300 repetitions/day: 3720 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 22 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 6270 kg
The Dynamic load for:
50 repetitions/day: 5260 kg
100 repetitions/day: 4850 kg
200 repetitions/day: 4350 kg
300 repetitions/day: 4030 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 22 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 6200 kg
The Dynamic load for:
50 repetitions/day: 5065 kg
100 repetitions/day: 4670 kg
200 repetitions/day: 4210 kg
300 repetitions/day: 3890 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 22 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 6600 kg
The Dynamic load for:
50 repetitions/day: 5500 kg
100 repetitions/day: 5100 kg
200 repetitions/day: 4550 kg
300 repetitions/day: 4220 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,5m - 6m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 23 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 6365 kg
The Dynamic load for:
50 repetitions/day: 5250 kg
100 repetitions/day: 4850 kg
200 repetitions/day: 4350 kg
300 repetitions/day: 4020 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 23 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 6745 kg
The Dynamic load for:
50 repetitions/day: 5700 kg
100 repetitions/day: 5260 kg
200 repetitions/day: 4720 kg
300 repetitions/day: 4375 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 23 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 6700 kg
The Dynamic load for:
50 repetitions/day: 5500 kg
100 repetitions/day: 5080 kg
200 repetitions/day: 4560 kg
300 repetitions/day: 4210 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7,5 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 23 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 7100 kg
The Dynamic load for:
50 repetitions/day: 5960 kg
100 repetitions/day: 5505 kg
200 repetitions/day: 4960 kg
300 repetitions/day: 4575 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 7,5 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 24 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 6840 kg
The Dynamic load for:
50 repetitions/day: 5670 kg
100 repetitions/day: 5230 kg
200 repetitions/day: 4680 kg
300 repetitions/day: 4350 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 8 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 24 cm

DOSAGE SUPER FIBRA BIGMAT AR: 2 kg / m³
The maximum permisible static point load is 7315 kg
The Dynamic load for:
50 repetitions/day: 6170 kg
100 repetitions/day: 5690 kg
200 repetitions/day: 5100 kg
300 repetitions/day: 4730 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 8 cm

CONCRETE C25 – 25 N/mm²

SLAB THICKNESS 24 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 7200 kg
The Dynamic load for:
50 repetitions/day: 5950 kg
100 repetitions/day: 5480 kg
200 repetitions/day: 4900 kg
300 repetitions/day: 4560 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 8 cm

CONCRETE C30 – 30 N/mm²

SLAB THICKNESS 24 cm

DOSAGE SUPER FIBRA BIGMAT AR: 3 kg / m³
The maximum permisible static point load is 7700 kg
The Dynamic load for:
50 repetitions/day: 6470 kg
100 repetitions/day: 5950 kg
200 repetitions/day: 5345 kg
300 repetitions/day: 4960 kg
The recommended distances between the shrinkage joints are:
Indoor slab: 4,75m - 6,5m
Outdoor slab: 4,5m - 6m
Depth of cut joint: 8 cm